Home > Archive > CCIE > December 2002 > CCIE Lab help





You are viewing an archived Text-only version of the thread. To view this thread in it's original format and/or if you want to reply to this thread please [click here]

Author CCIE Lab help
sailooo

2002-12-06, 11:54 am

Hi all,

Does anyone know what the pinouts are to connect back to back WIC-1DSU-T1's?

These are RJ-45 connectors and I want to connected them and built a FR cloud.

I've looked at cisco's website but did not find anything.

Any help would be greatly appreciated

Thanks in advance.
darthfeces

2002-12-06, 12:06 pm

SETTING UP BACK TO BACK CSU/DSU

This is for those working with the modular routers with the WIC-DSU-T1 cards installed.

The original document is now available at the Cisco web site. It was originally available only to internal Cisco SE’s

http://www.cisco.com/warp/public/471/75.html#command

You can connect 2 WIC1-T1-DSU Back to Back by using a Cross-Over cable between the CSU/DSUs.
Back-to-back configuration of the 4-wire CSU/DSU has the following restrictions:

You cannot use a clock rate of auto on either side of the back-to-back setup.
You cannot use a clock rate of 64.
You cannot use switched-56 operation.

Constructing a Cross-Over Cable

A 4 wire T-1 cross-over cable uses (1->4, 2->5, 4->1, 5->2)
A 4 wire 56k cross-over cable uses (1->7, 2->8, 7->1, 8->1)

T1 CSU/DSU Configuration

Set one CSU/DSU to clock source internal, and the other CSU/DSU to clock source line. The linecode, framing, data-coding, and timeslots must be set the same on both CSU/DSUs.

Four-Wire 56k CSU/DSU Configuration

Set one CSU/DSU to clock source internal, and the other CSU/DSU to clock source line. On the CSU/DSU with internal clock, the clock rate must not be auto. Both CSU/DSUs must be set for service-module 56k network-type dds.